comparE our Public lift models

We want you to find the perfect lift. The below table allows you to compare our different public lifts and find out which model suits your requirements and needs.

Nota bene: The cut-out sizes stated below are approximate and generic. For exact cut-out sizes, please refer to the project specific drawings provided by your Cibes dealer.

Lifts (max 4)

Description

Screw-driven platform lift without shaft

Screw-driven platform lift with ready-made shaft.

Screw-driven platform lift with ready-made shaft.

Screw-driven cabin lift with sliding doors, available with or without ready-made shaft.

Installation

Indoor/outdoor

Indoor

Indoor/outdoor

Indoor

Rated load

385 kg / 3 persons

1000 kg, 8-10 persons

400-500 kg, 4-5 persons

525 kg (1100×1200)
630 kg

Max travel (m)

3.0

13

13

15

Lift pit (mm)

0 mm / 60 mm

130 mm

50 mm / 0 mm

100 mm

Max no. of stops

2

6

6

6

Speed (m/s)

0.06

0.15

0.15

0.15

Lift sizes (w x d, mm)

900 x 1400

900 x 1600

1100 x 1400*

1100 x 1600

1105 x 2180

1405 x 1980

1405 x 2480

900 x 1467

1000 x 1467

1100 x 1467

1100 x 1597

1100 x 1967

WITH ready-made shaft

1100 x 1200

1100 x 1400

WITHOUT ready-made shaft

1100 x 1200

1100 x 1400

1100 x 1700

Cut-out sizes, single entry (w x d, mm)

1595 x 2310

1895 x 2110

1895 x 2610

1300 x 1630

1400 x 1630

1500 x 1630

1500 x 1760

1500 x 2130

WITH ready-made shaft

1610 x 1560 mm

1610 x 1740 mm

WITHOUT ready-made shaft

1550 x 1490 mm

1550 x 1690 mm

1550 x 1990 mm

Cut-out sizes, open-through (w x d, mm)

1595 x 2335

1895 x 2135

1895 x 2635

Same as above

WITH ready-made shaft

1610 x 1700 mm

1610 x 1900 mm

WITHOUT ready-made shaft

1550 x 1660 mm

1550 x 1860 mm

1550 x 2160 mm

Min. top height (mm)

2300

2250

2500

Door access

Straight-through

Adjacent*

Single entry

Open-through

Adjacent

Single entry

Open-through

Adjacent

Single entry

Open-through

Door type

Single-hinged gates

Single-hinged doors

Single-hinged doors (all floors)

Single-hinged gate (top floor)

Automatic sliding doors on landings and in cabin

Power supply

1 x 230 VAC, 16 A

3 x 400 VAC, 50 Hz, 16 A, 5 x 2,5 mm²

3 x 230 VAC, 50 Hz, 16 A, 5 x 2,5 mm²

1 x 230 VAC, 50 Hz, 16 A, 3 x 2,5 mm²

3 x 400 VAC, 50 Hz, 16 A, 5 x 2,5 mm²

3 x 230 VAC, 50 Hz, 16 A, 5 x 2,5 mm²

3 x 400 VAC, 50 Hz, 16 A, 5 x 2,5 mm²

3 x 230 VAC, 50 Hz, 16 A, 5 x 2,5 mm²

Standards

Machinery Directive 2006/42/EC

Machinery Directive 2006/42/EC

Machinery Directive 2006/42/EC

European Standard EN 81-41

Machinery Directive 2006/42/EC

Applicable parts of EN 81-41, 81-70 and 81-20